Systems we design, execute and commission
13 offerings, from the hydraulic design of a scheme to the commissioning of the installed system. Equipment comes from our own works, so supply and execution answer to one schedule.
Fire Protection System DesigningHydraulic designHazard assessment, hydraulic calculation, layouts and approval drawings for the consultant or insurer.
Foam Based Fire Fighting SystemNFPA 11Bladder tanks, pourers and makers for tank farms, bund areas and loading gantries.
Fire Hydrant SystemNFPA 24Plant-wide ring main, hydrants, monitors and hose boxes, sized to the site.
Fire Water Spray SystemNFPA 15Medium and high velocity spray for vessels, transformers and process equipment.
Rimseal Fire Protection SystemAPI 2021Detection and foam discharge at the seal of a floating roof tank.
Clean Agent Fire SuppressionNFPA 2001Gaseous suppression for control rooms, server rooms and cable galleries.
CO₂ Fire Suppression SystemNFPA 12Total flooding carbon dioxide for unoccupied electrical and machinery spaces.
Sprinkler SystemNFPA 13Wet, dry and pre-action systems for warehousing and buildings.
Water Curtain SystemNFPA 15Separation and exposure protection where spacing alone is not enough.
Fire Pump House and ReservoirNFPA 20Pumps, drivers, suction reservoir and controls — the source everything else runs on.
Fire Detection & Alarm SystemNFPA 72Detection and alarm, supplied and integrated under the same contract as the suppression system.
Gas Detection SystemIEC 60079-29Flammable and toxic gas detection for process areas, with alarm and shutdown.
Flame Detection SystemEN 54-10Optical flame detection for open process areas, fast enough to release deluge.
Which system for which hazard
The systems we apply to each hazard. Most installations combine several — detection that releases suppression, cooling beside foam.
| Hazard | Foam | Hydrant | Water spray | Rim seal | Clean agent | CO₂ | Sprinkler | Water curtain | Fire alarm | Gas detection | Flame detection |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Warehouse | Fire Hydrant System protects Warehouse | Sprinkler System protects Warehouse | Fire Detection & Alarm System protects Warehouse | ||||||||
| Transformers & Switchyards | Fire Hydrant System protects Transformers & Switchyards | Fire Water Spray System protects Transformers & Switchyards | Water Curtain System protects Transformers & Switchyards | ||||||||
| Truck & Rail Gantry | Foam Based Fire Fighting System protects Truck & Rail Gantry | Fire Hydrant System protects Truck & Rail Gantry | Fire Water Spray System protects Truck & Rail Gantry | Water Curtain System protects Truck & Rail Gantry | Gas Detection System protects Truck & Rail Gantry | Flame Detection System protects Truck & Rail Gantry | |||||
| Floating Roof Tanks | Foam Based Fire Fighting System protects Floating Roof Tanks | Fire Hydrant System protects Floating Roof Tanks | Rimseal Fire Protection System protects Floating Roof Tanks | ||||||||
| Aircraft Hangars | Foam Based Fire Fighting System protects Aircraft Hangars | Sprinkler System protects Aircraft Hangars | Fire Detection & Alarm System protects Aircraft Hangars | ||||||||
| Cable Galleries / Trenches | Fire Water Spray System protects Cable Galleries / Trenches | Clean Agent Fire Suppression protects Cable Galleries / Trenches | CO₂ Fire Suppression System protects Cable Galleries / Trenches | Fire Detection & Alarm System protects Cable Galleries / Trenches | |||||||
| Pipeline Manifolds | Fire Hydrant System protects Pipeline Manifolds | Fire Water Spray System protects Pipeline Manifolds | Gas Detection System protects Pipeline Manifolds | Flame Detection System protects Pipeline Manifolds | |||||||
| Fixed / Cone Roof Tanks | Foam Based Fire Fighting System protects Fixed / Cone Roof Tanks | Fire Hydrant System protects Fixed / Cone Roof Tanks | |||||||||
| Control Rooms & Substations | Clean Agent Fire Suppression protects Control Rooms & Substations | CO₂ Fire Suppression System protects Control Rooms & Substations | Fire Detection & Alarm System protects Control Rooms & Substations | ||||||||
| Pump & Compressor Areas | Fire Hydrant System protects Pump & Compressor Areas | Fire Water Spray System protects Pump & Compressor Areas | Gas Detection System protects Pump & Compressor Areas | Flame Detection System protects Pump & Compressor Areas | |||||||
| Conveyor Belts | Fire Hydrant System protects Conveyor Belts | Fire Water Spray System protects Conveyor Belts | Fire Detection & Alarm System protects Conveyor Belts | ||||||||
| Tank Farm Bund / Dyke | Foam Based Fire Fighting System protects Tank Farm Bund / Dyke | Fire Hydrant System protects Tank Farm Bund / Dyke | Gas Detection System protects Tank Farm Bund / Dyke | ||||||||
| Sphere & Bullet | Fire Hydrant System protects Sphere & Bullet | Fire Water Spray System protects Sphere & Bullet | Water Curtain System protects Sphere & Bullet | Gas Detection System protects Sphere & Bullet | Flame Detection System protects Sphere & Bullet |
Systems commissioned
- Photography to followReliance
Automatic rim seal fire protection system — Reliance
Automatic rim seal fire protection system for floating roof tanks for Reliance at Patalganga, Gadimoga, JNPT, Vadodara. · Patalganga, Gadimoga, JNPT, Vadodara
- Photography to followHPL
Automatic rim seal fire protection system — HPL
Automatic rim seal fire protection system for floating roof tanks for HPL at Haldia. · Haldia
- Photography to followBridge & Roof
Automatic rim seal fire protection system — Bridge & Roof
Automatic rim seal fire protection system for floating roof tanks for Bridge & Roof at IOCL Haldia, Paradip, Cochin, Mangalore, Narimannam, Tuticorin, Mourigram, Rajbandh, Siliguri, Barauni, Madurai, Devanganthi, Visakhapatnam, Korukkupet. · IOCL Haldia, Paradip, Cochin, Mangalore, Narimannam, Tuticorin, Mourigram, Rajbandh, Siliguri, Barauni, Madurai, Devanganthi, Visakhapatnam, Korukkupet
- Photography to followTata Memorial Hospital
Fire detection and alarm system — Tata Memorial Hospital
Fire detection and alarm system for Tata Memorial Hospital at Jamshedpur (JUSCO). · Jamshedpur (JUSCO)
- Photography to followIOTL
Foam system — IOTL
Foam based fire fighting system for IOTL at Vadinar. · Vadinar
- Photography to followAirports Authority of India
Foam system — Airports Authority of India
Foam based fire fighting system for Airports Authority of India at Kolkata. · Kolkata
- Photography to followTata Cummins
High velocity water spray system — Tata Cummins
High velocity water spray (HVWS) system for Tata Cummins at Jamshedpur. · Jamshedpur
- Photography to followTata Steel
Medium velocity water spray system — Tata Steel
Medium velocity water spray (MVWS) system for Tata Steel at Joda Mine. · Joda Mine
- Photography to followGAIL
Hydrant system — GAIL
Fire hydrant system for GAIL at Vijaipur. · Vijaipur
- Photography to followTISCO
Hydrant system — TISCO
Fire hydrant system for TISCO at Noamundi. · Noamundi
Considering us for a turnkey scope?
Send the hazard, the code and the site. Our engineers reply with a scheme and a price.