Systems we design, execute and commission
14 offerings, from the hydraulic design of a scheme to the commissioning of the installed system. Equipment comes from our own works, so supply and execution answer to one schedule.
Fire Protection System DesigningHydraulic designHazard assessment, hydraulic calculation, layouts and approval drawings for the consultant or insurer.
Foam Based Fire Fighting SystemNFPA 11Bladder tanks, pourers and makers for tank farms, bund areas and loading gantries.
Fire Hydrant SystemNFPA 24Plant-wide ring main, hydrants, monitors and hose boxes, sized to the site.
Fire Water Spray SystemNFPA 15Medium and high velocity spray for vessels, transformers and process equipment.
Rimseal Fire Protection SystemAPI 2021Detection and foam discharge at the seal of a floating roof tank.
Clean Agent Fire SuppressionNFPA 2001Gaseous suppression for control rooms, server rooms and cable galleries.
CO₂ Fire Suppression SystemNFPA 12Total flooding carbon dioxide for unoccupied electrical and machinery spaces.
Sprinkler SystemNFPA 13Wet, dry and pre-action systems for warehousing and buildings.
Water Mist SystemNFPA 750Fine water mist for turbines, machinery spaces, cable tunnels and electrical rooms.
Water Curtain SystemNFPA 15Separation and exposure protection where spacing alone is not enough.
Fire Pump House and ReservoirNFPA 20Pumps, drivers, suction reservoir and controls — the source everything else runs on.
Fire Detection & Alarm SystemNFPA 72Detection and alarm, supplied and integrated under the same contract as the suppression system.
Gas Detection SystemIEC 60079-29Flammable and toxic gas detection for process areas, with alarm and shutdown.
Flame Detection SystemEN 54-10Optical flame detection for open process areas, fast enough to release deluge.
Which system for which hazard
The systems we apply to each hazard. Most installations combine several — detection that releases suppression, cooling beside foam.
| Hazard | Foam Based Fire Fighting System | Fire Hydrant System | Fire Water Spray System | Rimseal Fire Protection System | Clean Agent Fire Suppression | CO₂ Fire Suppression System | Sprinkler System | Water Mist System | Water Curtain System | Fire Detection & Alarm System | Gas Detection System | Flame Detection System |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Transformers & Switchyards | Fire Hydrant System protects Transformers & Switchyards | Fire Water Spray System protects Transformers & Switchyards | Water Mist System protects Transformers & Switchyards | Water Curtain System protects Transformers & Switchyards | ||||||||
| Truck & Rail Gantry | Foam Based Fire Fighting System protects Truck & Rail Gantry | Fire Hydrant System protects Truck & Rail Gantry | Fire Water Spray System protects Truck & Rail Gantry | Water Curtain System protects Truck & Rail Gantry | Gas Detection System protects Truck & Rail Gantry | Flame Detection System protects Truck & Rail Gantry | ||||||
| Floating Roof Tanks | Foam Based Fire Fighting System protects Floating Roof Tanks | Fire Hydrant System protects Floating Roof Tanks | Rimseal Fire Protection System protects Floating Roof Tanks | |||||||||
| Cable Galleries / Trenches | Fire Water Spray System protects Cable Galleries / Trenches | Clean Agent Fire Suppression protects Cable Galleries / Trenches | CO₂ Fire Suppression System protects Cable Galleries / Trenches | Water Mist System protects Cable Galleries / Trenches | Fire Detection & Alarm System protects Cable Galleries / Trenches | |||||||
| Pipeline Manifolds | Fire Hydrant System protects Pipeline Manifolds | Fire Water Spray System protects Pipeline Manifolds | Gas Detection System protects Pipeline Manifolds | Flame Detection System protects Pipeline Manifolds | ||||||||
| Fixed / Cone Roof Tanks | Foam Based Fire Fighting System protects Fixed / Cone Roof Tanks | Fire Hydrant System protects Fixed / Cone Roof Tanks | ||||||||||
| Warehouses | Fire Hydrant System protects Warehouses | Sprinkler System protects Warehouses | Fire Detection & Alarm System protects Warehouses | |||||||||
| Pump & Compressor Areas | Fire Hydrant System protects Pump & Compressor Areas | Fire Water Spray System protects Pump & Compressor Areas | Water Mist System protects Pump & Compressor Areas | Gas Detection System protects Pump & Compressor Areas | Flame Detection System protects Pump & Compressor Areas | |||||||
| Conveyor Belts | Fire Hydrant System protects Conveyor Belts | Fire Water Spray System protects Conveyor Belts | Fire Detection & Alarm System protects Conveyor Belts | |||||||||
| Tank Farm Bund / Dyke | Foam Based Fire Fighting System protects Tank Farm Bund / Dyke | Fire Hydrant System protects Tank Farm Bund / Dyke | Gas Detection System protects Tank Farm Bund / Dyke | |||||||||
| Control Rooms & Substations | Clean Agent Fire Suppression protects Control Rooms & Substations | CO₂ Fire Suppression System protects Control Rooms & Substations | Water Mist System protects Control Rooms & Substations | Fire Detection & Alarm System protects Control Rooms & Substations | ||||||||
| Aircraft Hangars | Foam Based Fire Fighting System protects Aircraft Hangars | Sprinkler System protects Aircraft Hangars | Fire Detection & Alarm System protects Aircraft Hangars | |||||||||
| Sphere & Bullet | Fire Hydrant System protects Sphere & Bullet | Fire Water Spray System protects Sphere & Bullet | Water Curtain System protects Sphere & Bullet | Gas Detection System protects Sphere & Bullet | Flame Detection System protects Sphere & Bullet |
Systems commissioned
Tata SteelHigh velocity water spray system — Tata Steel
High velocity water spray (HVWS) system for Tata Steel at Joda Mine. · Joda Mine
RelianceAutomatic rim seal fire protection system — Reliance
Automatic rim seal fire protection system for floating roof tanks for Reliance at four sites. · Patalganga, Gadimoga, JNPT, Vadodara
Oil IndiaHydrant system — Oil India
Fire hydrant system for Oil India at Duliajan. · Duliajan
ONGCInert gas based fire suppression system — ONGC
Inert gas based fire suppression system for ONGC at four sites. · Geleki, Bokaro, Tripura, Mehsana Asset
GAILMedium velocity water spray system — GAIL
Medium velocity water spray (MVWS) system for GAIL at Vijaipur. · Vijaipur
HPCLAutomatic rim seal fire protection system — HPCL
Automatic rim seal fire protection system for floating roof tanks for HPCL at two sites. · Visakhapatnam, Barauni
Berger PaintsHydrant system — Berger Paints
Fire hydrant system for Berger Paints at three sites. · Sandila, Anand, Naltali
Bridge & RoofFoam system — Bridge & Roof
Foam based fire fighting system for Bridge & Roof at two sites. · IOCL Trichy and Sankari depot, CPCL
GAILHigh velocity water spray system — GAIL
High velocity water spray (HVWS) system for GAIL at Vijaipur. · Vijaipur
IOCLAutomatic rim seal fire protection system — IOCL
Automatic rim seal fire protection system for floating roof tanks for IOCL at three sites. · Barauni, AOD, Paradip
RINLInert gas based fire suppression system — RINL
Inert gas based fire suppression system for RINL at Visakhapatnam Steel Plant. · Visakhapatnam Steel Plant
IOTLFoam system — IOTL
Foam based fire fighting system for IOTL at Vadinar. · Vadinar
Berger PaintsMedium velocity water spray system — Berger Paints
Medium velocity water spray (MVWS) system for Berger Paints at three sites. · Sandila, Shibpur, Anand
TISCOHydrant system — TISCO
Fire hydrant system for TISCO at Noamundi. · Noamundi
HPLAutomatic rim seal fire protection system — HPL
Automatic rim seal fire protection system for floating roof tanks for HPL at Haldia. · Haldia
BPCLFoam system — BPCL
Foam based fire fighting system for BPCL at three sites. · Haldia, Malda, New Jalpaiguri
Tata CumminsHigh velocity water spray system — Tata Cummins
High velocity water spray (HVWS) system for Tata Cummins at Jamshedpur. · Jamshedpur
BHELHydrant system — BHEL
Fire hydrant system for BHEL at Haldia. · Haldia
MECONInert gas based fire suppression system — MECON
Inert gas based fire suppression system for MECON at Ranchi. · Ranchi
IOCLFire detection and alarm system — IOCL
Fire detection and alarm system for IOCL at six sites. · Bongaigaon, Haldia, Barauni, DDPL Bangalore, Quilon, HBCPL
IOCLMedium velocity water spray system — IOCL
Medium velocity water spray (MVWS) system for IOCL at five sites. · PJPL, Panipat Refinery, Barauni Refinery, Tikrikalan bottling plant, Kalyani
Oil IndiaAutomatic rim seal fire protection system — Oil India
Automatic rim seal fire protection system for floating roof tanks for Oil India at Duliajan. · Duliajan
Airports Authority of IndiaFoam system — Airports Authority of India
Foam based fire fighting system for Airports Authority of India at Kolkata. · Kolkata
GAILFire detection and alarm system — GAIL
Fire detection and alarm system for GAIL at two sites. · Vijaipur, Gandhar
Oil IndiaMedium velocity water spray system — Oil India
Medium velocity water spray (MVWS) system for Oil India at Duliajan. · Duliajan
IOCLHydrant system — IOCL
Fire hydrant system for IOCL at six sites. · Coimbatore, Quilon, Hasimara, Dharmanagar, Kalyani, Goindwal
Bridge & RoofAutomatic rim seal fire protection system — Bridge & Roof
Automatic rim seal fire protection system for floating roof tanks for Bridge & Roof at 14 sites. · IOCL Haldia, Paradip, Cochin, Mangalore, Narimannam, Tuticorin, Mourigram, Rajbandh, Siliguri, Barauni, Madurai, Devanganthi, Visakhapatnam, Korukkupet
IOCLInert gas based fire suppression system — IOCL
Inert gas based fire suppression system for IOCL at two sites. · Barauni, Mathura
Tata SteelMedium velocity water spray system — Tata Steel
Medium velocity water spray (MVWS) system for Tata Steel at Joda Mine. · Joda Mine
IOCLCO₂ system — IOCL
Carbon dioxide fire suppression system for IOCL at six sites. · Barauni Refinery, Haldia Refinery, Kohand, Jalandhar, Nabha, Sidhpur
Berger PaintsFoam system — Berger Paints
Foam based fire fighting system for Berger Paints at three sites. · Naltali, Pune, Sandila
BPCLGas detection system — BPCL
Gas detection system for BPCL at two sites. · Rajkot, Fatuha (Patna)
IOCLHigh velocity water spray system — IOCL
High velocity water spray (HVWS) system for IOCL at three sites. · Panipat, Haldia Refinery, Digboi
Bridge & RoofAutomatic rim seal fire protection system — Bridge & Roof
Automatic rim seal fire protection system for floating roof tanks for Bridge & Roof at six sites. · BPCL Bina, Manmad, Irimpanam, Manglya, Piyala, Kandla
Tata MotorsInert gas based fire suppression system — Tata Motors
Inert gas based fire suppression system for Tata Motors at Jamshedpur. · Jamshedpur
Tata Memorial HospitalFire detection and alarm system — Tata Memorial Hospital
Fire detection and alarm system for Tata Memorial Hospital at Jamshedpur (JUSCO). · Jamshedpur (JUSCO)
Airports Authority of IndiaHydrant system — Airports Authority of India
Fire hydrant system for Airports Authority of India at Kolkata. · Kolkata
IOCLFoam system — IOCL
Foam based fire fighting system for IOCL at five sites. · Hasimara, Mourigram, Dharmanagar, Rajola, Rewari
NRLCO₂ system — NRL
Carbon dioxide fire suppression system for NRL at Assam. · Assam
BPCLAutomatic rim seal fire protection system — BPCL
Automatic rim seal fire protection system for floating roof tanks for BPCL at Krishnapatnam. · Krishnapatnam
BPCLMedium velocity water spray system — BPCL
Medium velocity water spray (MVWS) system for BPCL at eight sites. · Tuticorin, Solur, Gummidipoondi, Cherlapally, Patna, Vijayawada, Hariyala, Rajkot
IOCLGas detection system — IOCL
Gas detection system for IOCL at five sites. · Barauni Refinery, Haldia, Kohand, Nabha, Jalandhar
GAILHydrant system — GAIL
Fire hydrant system for GAIL at Vijaipur. · Vijaipur
GAILInert gas based fire suppression system — GAIL
Inert gas based fire suppression system for GAIL at Usar. · Usar
Airports Authority of IndiaFire detection and alarm system — Airports Authority of India
Fire detection and alarm system for Airports Authority of India at Kolkata. · Kolkata
Considering us for a turnkey scope?
Send the hazard, the code and the site. Our engineers reply with a scheme and a price.