Fabricated Y Strainer
Named for its shape, and the most economical choice for removing large debris. Cast in 1" to 24" with threaded, socket weld or flanged end connections.
At a glance
- Size range
- 1" to 24"
- End connections
- Threaded, socket weld or flanged
- Pressure drop data
- 2" to 24"
Specification
| Size range | 1" to 24" |
|---|---|
| End connections | Threaded, socket weld, flanged, welded or grooved |
| Service | High pressure and temperature duties, and high viscosity services, where a sturdy screen is required |
| Pressure drop data | Published for 2" to 24" |
| Rating | ASME Class 150 to 2500 |
| Flange type | SORF or WNRF |
| Body material | IS 2062, SA 516 Gr. 70, A 106 or stainless steel |
| Element | SS 316 or duplex steel |
| Element design | UL 331 |
| Flange material | IS 2062, A 105 or stainless steel |
| Bolts and nuts | Carbon steel or stainless steel |
| Screen | Open area | Opening |
|---|---|---|
| Perforated, IPA 120 | 58% | — |
| Perforated, IPA 118 | 51% | — |
| Perforated, IPA 113 | 40% | — |
| Perforated, IPA 106 | 23% | — |
| Perforated, IPA 102 | 23% | — |
| 20 mesh | 49% | 0.035" |
| 30 mesh | 45% | 0.022" |
| 40 mesh | 41% | 0.016" |
| 60 mesh | 38% | 0.010" |
| 80 mesh | 36% | 0.008" |
| 100 mesh | 30% | 0.006" |
Construction & operation
Y-strainers take their name from their shape. Made in sizes from 1" to 24", with threaded, socket weld or flanged ends, they are the most economical choice for removing large debris.
Suited to services that need an extremely sturdy screen: high pressure and temperature duties, and high viscosity fluids.
Filtration level. When choosing a perforation or a mesh-and-perforation combination, avoid overstraining: as a rule the specified filtration should be no finer than half the size of the particle to be removed. Too fine a filtration raises the pressure drop very rapidly and can damage the basket.
Where it is used
Part of these fire fighting solutions
Fire Hydrant SystemPlant-wide ring main, hydrants, monitors and hose boxes, sized to the site.
Fire Pump House and ReservoirPumps, drivers, suction reservoir and controls — the source everything else runs on.
Fire Water Spray SystemMedium and high velocity spray for vessels, transformers and process equipment.
Specified for these hazards
Cable Galleries / TrenchesLinear heat detection with water spray or clean agent.
Conveyor BeltsLinear detection and deluge along the belt run.
Pipeline ManifoldsSpray protection at valve and manifold congestion.
Pump & Compressor AreasSpray protection over rotating equipment and seal leakage points.
Sphere & BulletWater spray for cooling and exposure protection on pressurised storage.
Transformers & SwitchyardsHigh velocity water spray, with drainage and separation designed in.
Truck & Rail GantryFoam and water spray over loading bays, with detection at the arms.
Downloads
- Product datasheetPDF ↓
Related products
Send us a specification
Give us the duty, the medium and the standard. We reply with a selection and a price.